Sari la conținut
Coșul meu

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Human IL-8 ELISA Kit (High Sensitivity)

Pe scurt

Human IL-8 ELISA Kit (High Sensitivity) este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea IL-8, cu reactivitate declarată pentru Human. Măsoară în domeniul 0.47-30 pg/ml, are o sensibilitate de 0.29 pg/ml, folosește detecție Colorimetric Detection (OD450) și se poate folosi pe probe de tip Serum, plasma and other biological fluids. Se livrează în mărimea 96T, la prețul de 3.360,78 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Human IL-8 ELISA Kit is a high sensitivity sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human IL-8 in serum, plasma, and other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărime
96T
Țintă
IL-8
Applications
Sandwich ELISA
Reactivity
Human
Sensitivity
0.29 pg/ml
Product range
0.47-30 pg/ml
Assay Time
3h 30m
Principiul testului
Human IL-8 ELISA Kit (A323171) employs the sandwich Enzyme-Linked Immunoassay technique for the quantitative measurement of low-abundance human IL-8 in serum, plasma, and other biological fluids. An antibody specific for IL-8 has been pre-coated onto a 96-well microtiter plate. The standards and test samples are added into the wells and the IL-8 present in each sample is bound to the wells by the immobilized antibody. Following incubation, the wells are washed and then incubated with Biotinylated Anti-IL-8 Antibody, which binds the captured IL-8 present in each well. Following incubation, unbound biotinylated detection antibody is removed by washing, and an HRP-Avidin conjugate is added to the wells and the microtiter plate is incubated. Following incubation and washing, TMB substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is proportional to the amount of IL-8 captured in each well. The concentration of IL-8 can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.