Imagine indisponibilăHuman Humanin/MT-RNR2 ELISA Kit
Pe scurt
Human Humanin/MT-RNR2 ELISA Kit este un kit ELISA de tip Competitive (quantitative) pentru măsurarea Humanin/MT-RNR2, cu reactivitate declarată pentru Human. Măsoară în domeniul 0.146-600 pg/ml, are o sensibilitate de 0.12 pg/ml, folosește detecție Colorimetric Detection (OD450) și se poate folosi pe probe de tip Serum, plasma, tissue homogenates, and other biological fluids. Se livrează în mărimea 96T, la prețul de 4.625,23 lei cu TVA.
Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.
Descriere
Human Humanin/MT-RNR2 ELISA Kit is a competitive Enzyme-Linked Immunosorbent Assay (cELISA) designed for the in vitro quantitative determination of human Humanin/MT-RNR2 in serum, plasma, tissue homogenates, and other biological fluids.
Citește mai multArată mai puțin
Specificații
- Brand
- Antibodies
- Mărime
- 96T
- Țintă
- Humanin/MT-RNR2
- Applications
- Competitive ELISA
- Reactivity
- Human
- Assay type
- Competitive (quantitative)
- Sensitivity
- 0.12 pg/ml
- Cross reactivity
- Specific for Humanin/MT-RNR2 with no reported cross-reactivity with other analogs or variants.
- Detection type
- Colorimetric Detection (OD450)
- Product range
- 0.146-600 pg/ml
- Assay Time
- 2 hours
- Principiul testului
- Human Humanin/MT-RNR2 ELISA Kit (A247118) is a 2 hour competitive Enzyme-Linked Immunosorbent Assay (cELISA) designed for the in vitro quantitative determination of human Humanin/MT-RNR2 in serum, plasma, tissue homogenates, and other biological fluids. A 96-well microtiter plate has been pre-coated with Humanin/MT-RNR2. During the assay, Humanin/MT-RNR2 present in the standards or samples competes with immobilized Humanin/MT-RNR2 for binding to an assay-specific antibody. Following incubation, unbound components are removed by washing and HRP-Streptavidin conjugate is added to the wells. After further incubation and washing, TMB substrate solution is added to visualize the HRP enzymatic reaction. This produces a blue-coloured product that changes to yellow following addition of acidic stop solution. The intensity of the colour is measured at 450 nm using a microplate reader. The concentration of Humanin/MT-RNR2 in the samples is inversely proportional to the OD450 value and is determined by comparison with the standard curve.
Documentație
Produse similare
Imagine indisponibilă
Imagine indisponibilă
Imagine indisponibilă
Imagine indisponibilăAntibodiesA247120Universal 3-Methoxy-4-hydroxyphenylglycol ELISA Kit
4.392,30 lei3.630,00 leiTVA inclus (21%)fără TVA
Imagine indisponibilă
Imagine indisponibilă
Imagine indisponibilă
Imagine indisponibilă
Imagine indisponibilă
Imagine indisponibilă
Imagine indisponibilă
Imagine indisponibilă