Human HRH1/H1R ELISA Kit

Pe scurt

Human HRH1/H1R ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea HRH1/H1R, cu reactivitate declarată pentru Human. Măsoară în domeniul 31.25 - 2000 pg/ml, are o sensibilitate de 18.75 pg/ml, folosește detecție Colorimetric Detection (OD450) și se poate folosi pe probe de tip Serum, plasma, tissue homogenates, and other biological fluids. Se livrează în mărimea 96T, la prețul de 4.591,95 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Human HRH1/H1R ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human HRH1/H1R in serum, plasma, tissue homogenates, and other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărime
96T
Țintă
HRH1/H1R
Applications
Sandwich ELISA
Reactivity
Human
Sensitivity
18.75 pg/ml
Product range
31.25 - 2000 pg/ml
Assay Time
4 hours
Principiul testului
Human HRH1/H1R ELISA Kit (A303131) is a 4 hour sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human HRH1/H1R in serum, plasma, tissue homogenates, and other biological fluids. A 96-well microtiter plate has been pre-coated with an antibody specific for HRH1/H1R. Standards and samples are added to the wells, where HRH1/H1R binds to the immobilized capture antibody. Following incubation, unbound components are removed by washing and a biotinylated detection antibody specific for HRH1/H1R is added to the wells. The detection antibody binds the captured HRH1/H1R to form an antibody-antigen-antibody sandwich complex. After further incubation and washing, HRP-Streptavidin conjugate is added to the wells. TMB substrate solution is then added to visualize the HRP enzymatic reaction. This produces a blue-coloured product that changes to yellow following addition of acidic stop solution. The intensity of the yellow colour is directly proportional to the amount of HRH1/H1R captured in each well. The concentration of HRH1/H1R is calculated by reading the absorbance at 450 nm and comparing the values with the standard curve.