Human hnRNP U/p120 ELISA Kit

Pe scurt

Human hnRNP U/p120 ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea hnRNP U/p120, cu reactivitate declarată pentru Human. Măsoară în domeniul 0.156-10 ng/ml, are o sensibilitate de 0.057 ng/ml, folosește detecție Colourmetric și se poate folosi pe probe de tip Tissue homogenates or other biological fluids. Se livrează în mărimile 48T și 96T, la prețuri între 4.259,20 și 5.523,65 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Human hnRNP U/p120 ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human hnRNP U/p120 in tissue homogenates or other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărimi disponibile
48T · 96T
Applications
Sandwich ELISA
Reactivity
Human
Sensitivity
0.057 ng/ml
Detection type
Colourmetric
Product range
0.156-10 ng/ml
Assay Time
4h 30m
Principiul testului
Human hnRNP U/p120 ELISA Kit (A5648) employs the sandwich enzyme immunoassay technique for the quantitative measurement of human hnRNP U/p120 in tissue homogenates or other biological fluids. An antibody specific for hnRNP U/p120 has been pre-coated onto a 96-well microtiter plate. The standards and test samples are added into the wells and the hnRNP U/p120 present in each sample is bound to the wells by the immobilized antibody. Following incubation, the wells are washed and then incubated with Biotinylated Anti-hnRNP U/p120 Antibody, which binds the captured hnRNP U/p120 present in each well. HRP-Avidin conjugate is then added to the wells and the microtiter plate is incubated. Following incubation and washing, TMB substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is proportional to the amount of hnRNP U/p120 captured in each well. The concentration of hnRNP U/p120 can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.