Human GPRC5A ELISA Kit

Pe scurt

Human GPRC5A ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea GPRC5A, cu reactivitate declarată pentru Human. Măsoară în domeniul 0.312-20 ng/ml, are o sensibilitate de 0.116 ng/ml, folosește detecție Colourmetric și se poate folosi pe probe de tip Tissue homogenates, cell lysates or other biological fluids. Se livrează în mărimile 48T și 96T, la prețuri între 4.525,40 și 5.989,50 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Human GPRC5A ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human GPRC5A in tissue homogenates, cell lysates or other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărimi disponibile
48T · 96T
Țintă
GPRC5A
Applications
Sandwich ELISA
Reactivity
Human
Sensitivity
0.116 ng/ml
Detection type
Colourmetric
Product range
0.312-20 ng/ml
Assay Time
4h 30m
Principiul testului
Human GPRC5A ELISA Kit (A6198) employs the sandwich enzyme immunoassay technique for the quantitative measurement of human GPRC5A in tissue homogenates, cell lysates or other biological fluids. An antibody specific for GPRC5A has been pre-coated onto a 96-well microtiter plate. The standards and test samples are added into the wells and the GPRC5A present in each sample is bound to the wells by the immobilized antibody. Following incubation, the wells are washed and then incubated with Biotinylated Anti-GPRC5A Antibody, which binds the captured GPRC5A present in each well. HRP-Avidin conjugate is then added to the wells and the microtiter plate is incubated. Following incubation and washing, TMB substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is proportional to the amount of GPRC5A captured in each well. The concentration of GPRC5A can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.