Human GluN2D ELISA Kit

Pe scurt

Human GluN2D ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea GluN2D, cu reactivitate declarată pentru Human. Măsoară în domeniul 0.312-20 ng/ml, are o sensibilitate de 0.123 ng/ml, folosește detecție Colourmetric și se poate folosi pe probe de tip Tissue homogenates or other biological fluids. Se livrează în mărimile 48T și 96T, la prețuri între 4.259,20 și 5.523,65 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Human GluN2D ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human GluN2D in tissue homogenates or other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărimi disponibile
48T · 96T
Țintă
GluN2D
Applications
Sandwich ELISA
Reactivity
Human
Sensitivity
0.123 ng/ml
Detection type
Colourmetric
Product range
0.312-20 ng/ml
Assay Time
4h 30m
Principiul testului
Human GluN2D ELISA Kit (A7386) employs the sandwich enzyme immunoassay technique for the quantitative measurement of human GluN2D in tissue homogenates or other biological fluids. An antibody specific for GluN2D has been pre-coated onto a 96-well microtiter plate. The standards and test samples are added into the wells and the GluN2D present in each sample is bound to the wells by the immobilized antibody. Following incubation, the wells are washed and then incubated with Biotinylated Anti-GluN2D Antibody, which binds the captured GluN2D present in each well. HRP-Avidin conjugate is then added to the wells and the microtiter plate is incubated. Following incubation and washing, TMB substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is proportional to the amount of GluN2D captured in each well. The concentration of GluN2D can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.