Human Flt3 Ligand/Flt3L ELISA Kit

Pe scurt

Human Flt3 Ligand/Flt3L ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea Flt3 Ligand/Flt3L, cu reactivitate declarată pentru Human. Măsoară în domeniul 15.6-1000 pg/ml, are o sensibilitate de 7.5 pg/ml, folosește detecție Colourmetric și se poate folosi pe probe de tip Serum, plasma, tissue homogenates or other biological fluids. Se livrează în mărimile 48T și 96T, la prețuri între 3.194,40 și 4.026,28 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Human Flt3 Ligand/Flt3L ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human Flt3 Ligand/Flt3L in serum, plasma, tissue homogenates or other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărimi disponibile
48T · 96T
Applications
Sandwich ELISA
Reactivity
Human
Sensitivity
7.5 pg/ml
Detection type
Colourmetric
Product range
15.6-1000 pg/ml
Assay Time
4h 30m
Principiul testului
Human Flt3 Ligand/Flt3L ELISA Kit (A1698) employs the sandwich enzyme immunoassay technique for the quantitative measurement of human Flt3 Ligand/Flt3L in serum, plasma, tissue homogenates or other biological fluids. An antibody specific for Flt3 Ligand/Flt3L has been pre-coated onto a 96-well microtiter plate. The standards and test samples are added into the wells and the Flt3 Ligand/Flt3L present in each sample is bound to the wells by the immobilized antibody. Following incubation, the wells are washed and then incubated with Biotinylated Anti-Flt3 Ligand/Flt3L Antibody, which binds the captured Flt3 Ligand/Flt3L present in each well. HRP-Avidin conjugate is then added to the wells and the microtiter plate is incubated. Following incubation and washing, TMB substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is proportional to the amount of Flt3 Ligand/Flt3L captured in each well. The concentration of Flt3 Ligand/Flt3L can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.