Human FGF9/GAF ELISA Kit

Pe scurt

Human FGF9/GAF ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea FGF9/GAF, cu reactivitate declarată pentru Human. Măsoară în domeniul 0.156-10 ng/ml, are o sensibilitate de 0.064 ng/ml și folosește detecție Colourmetric. Se livrează în mărimile 48T și 96T, la prețuri între 3.560,43 și 4.625,23 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Human FGF9/GAF ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human FGF9/GAF in serum, plasma, tissue homogenates, cell lysates, cell culture supernates or other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărimi disponibile
48T · 96T
Țintă
FGF9/GAF
Applications
Sandwich ELISA
Reactivity
Human
Sensitivity
0.064 ng/ml
Detection type
Colourmetric
Product range
0.156-10 ng/ml
Assay Time
4h 30m
Principiul testului
Human FGF9/GAF ELISA Kit (A1694) employs the sandwich enzyme immunoassay technique for the quantitative measurement of human FGF9/GAF in serum, plasma, tissue homogenates, cell lysates, cell culture supernates or other biological fluids. An antibody specific for FGF9/GAF has been pre-coated onto a 96-well microtiter plate. The standards and test samples are added into the wells and the FGF9/GAF present in each sample is bound to the wells by the immobilized antibody. Following incubation, the wells are washed and then incubated with Biotinylated Anti-FGF9/GAF Antibody, which binds the captured FGF9/GAF present in each well. HRP-Avidin conjugate is then added to the wells and the microtiter plate is incubated. Following incubation and washing, TMB substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is proportional to the amount of FGF9/GAF captured in each well. The concentration of FGF9/GAF can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.