Sari la conținut
Coșul meu

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Human Fetal Hemoglobin ELISA Kit

Pe scurt

Human Fetal Hemoglobin ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea Fetal Hemoglobin, cu reactivitate declarată pentru Human. Măsoară în domeniul 469-30000 ng/ml, are o sensibilitate de 122.6 ng/ml, folosește detecție Colourmetric și se poate folosi pe probe de tip Serum, plasma or erythrocyte lysates. Se livrează în mărimile 48T și 96T, la prețuri între 4.259,20 și 5.523,65 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Human Fetal Hemoglobin ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human Fetal Hemoglobin in serum, plasma or erythrocyte lysates.

Citește mai multArată mai puțin

Specificații

Mărimi disponibile
48T · 96T
Applications
Sandwich ELISA
Reactivity
Human
Sensitivity
122.6 ng/ml
Detection type
Colourmetric
Product range
469-30000 ng/ml
Assay Time
4h 30m
Principiul testului
Human Fetal Hemoglobin ELISA Kit (A6655) employs the sandwich enzyme immunoassay technique for the quantitative measurement of human Fetal Hemoglobin in serum, plasma or erythrocyte lysates. An antibody specific for Fetal Hemoglobin has been pre-coated onto a 96-well microtiter plate. The standards and test samples are added into the wells and the Fetal Hemoglobin present in each sample is bound to the wells by the immobilized antibody. Following incubation, the wells are washed and then incubated with Biotinylated Anti-Fetal Hemoglobin Antibody, which binds the captured Fetal Hemoglobin present in each well. HRP-Avidin conjugate is then added to the wells and the microtiter plate is incubated. Following incubation and washing, TMB substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is proportional to the amount of Fetal Hemoglobin captured in each well. The concentration of Fetal Hemoglobin can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.

Documentație

Produse similare

Ai nevoie de ajutor?

Nu găsești produsul potrivit? Scrie-ne cerințele și îți răspundem cu o recomandare și un preț.

Solicită consultanță

Achiziții publice

Suntem înregistrați în SEAP și livrăm către instituții publice, cu documentație completă.

Cum cumperi prin SEAP →

Contact