Imagine indisponibilăHuman eIF3A ELISA Kit
Pe scurt
Human eIF3A ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea eIF3A, cu reactivitate declarată pentru Human. Măsoară în domeniul 0.313-20 ng/ml, are o sensibilitate de 0.188 ng/ml, folosește detecție Colorimetric Detection (OD450) și se poate folosi pe probe de tip Serum, plasma, tissue homogenates, and other biological fluids. Se livrează în mărimea 96T, la prețul de 4.392,30 lei cu TVA.
Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.
Descriere
Human eIF3A ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human eIF3A in serum, plasma, tissue homogenates, and other biological fluids.
Citește mai multArată mai puțin
Specificații
- Brand
- Antibodies
- Mărime
- 96T
- Țintă
- eIF3A
- Applications
- Sandwich ELISA
- Reactivity
- Human
- Assay type
- Sandwich (quantitative)
- Sensitivity
- 0.188 ng/ml
- Cross reactivity
- Specific for eIF3A with no reported cross-reactivity with other analogs or variants.
- Detection type
- Colorimetric Detection (OD450)
- Product range
- 0.313-20 ng/ml
- Assay Time
- 4 hours
- Principiul testului
- Human eIF3A ELISA Kit (A76477) is a 4 hour sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human eIF3A in serum, plasma, tissue homogenates, and other biological fluids. A 96-well microtiter plate has been pre-coated with an antibody specific for eIF3A. Standards and samples are added to the wells, where eIF3A binds to the immobilized capture antibody. Following incubation, unbound components are removed by washing and a biotinylated detection antibody specific for eIF3A is added to the wells. The detection antibody binds the captured eIF3A to form an antibody-antigen-antibody sandwich complex. After further incubation and washing, HRP-Streptavidin conjugate is added to the wells. TMB substrate solution is then added to visualize the HRP enzymatic reaction. This produces a blue-coloured product that changes to yellow following addition of acidic stop solution. The intensity of the yellow colour is directly proportional to the amount of eIF3A captured in each well. The concentration of eIF3A is calculated by reading the absorbance at 450 nm and comparing the values with the standard curve.
Documentație
Produse similare