Human Dicer ELISA Kit

Pe scurt

Human Dicer ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea Dicer, cu reactivitate declarată pentru Human. Măsoară în domeniul 0.313-20 ng/ml, are o sensibilitate de 0.188 ng/ml, folosește detecție Colorimetric Detection (OD450) și se poate folosi pe probe de tip Serum, plasma, tissue homogenates, and other biological fluids. Se livrează în mărimea 96T, la prețul de 4.392,30 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Human Dicer ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human Dicer in serum, plasma, tissue homogenates, and other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărime
96T
Țintă
Dicer
Applications
Sandwich ELISA
Reactivity
Human
Sensitivity
0.188 ng/ml
Product range
0.313-20 ng/ml
Assay Time
4 hours
Principiul testului
Human Dicer ELISA Kit (A75369) is a 4 hour sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human Dicer in serum, plasma, tissue homogenates, and other biological fluids. A 96-well microtiter plate has been pre-coated with an antibody specific for Dicer. Standards and samples are added to the wells, where Dicer binds to the immobilized capture antibody. Following incubation, unbound components are removed by washing and a biotinylated detection antibody specific for Dicer is added to the wells. The detection antibody binds the captured Dicer to form an antibody-antigen-antibody sandwich complex. After further incubation and washing, HRP-Streptavidin conjugate is added to the wells. TMB substrate solution is then added to visualize the HRP enzymatic reaction. This produces a blue-coloured product that changes to yellow following addition of acidic stop solution. The intensity of the yellow colour is directly proportional to the amount of Dicer captured in each well. The concentration of Dicer is calculated by reading the absorbance at 450 nm and comparing the values with the standard curve.