Sari la conținut
Coșul meu

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Human DC-SIGNR ELISA Kit

Pe scurt

Human DC-SIGNR ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea DC-SIGNR, cu reactivitate declarată pentru Human. Măsoară în domeniul 3.125-200 ng/ml, are o sensibilitate de 1.875 ng/ml, folosește detecție Colorimetric Detection (OD450) și se poate folosi pe probe de tip Serum, plasma, tissue homogenates, and other biological fluids. Se livrează în mărimea 96T, la prețul de 4.392,30 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Human DC-SIGNR ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human DC-SIGNR in serum, plasma, tissue homogenates, and other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărime
96T
Țintă
DC-SIGNR
Applications
Sandwich ELISA
Reactivity
Human
Sensitivity
1.875 ng/ml
Product range
3.125-200 ng/ml
Assay Time
4 hours
Principiul testului
Human DC-SIGNR ELISA Kit (A247407) is a 4 hour sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human DC-SIGNR in serum, plasma, tissue homogenates, and other biological fluids. A 96-well microtiter plate has been pre-coated with an antibody specific for DC-SIGNR. Standards and samples are added to the wells, where DC-SIGNR binds to the immobilized capture antibody. Following incubation, unbound components are removed by washing and a biotinylated detection antibody specific for DC-SIGNR is added to the wells. The detection antibody binds the captured DC-SIGNR to form an antibody-antigen-antibody sandwich complex. After further incubation and washing, HRP-Streptavidin conjugate is added to the wells. TMB substrate solution is then added to visualize the HRP enzymatic reaction. This produces a blue-coloured product that changes to yellow following addition of acidic stop solution. The intensity of the yellow colour is directly proportional to the amount of DC-SIGNR captured in each well. The concentration of DC-SIGNR is calculated by reading the absorbance at 450 nm and comparing the values with the standard curve.

Documentație

Produse similare

Ai nevoie de ajutor?

Nu găsești produsul potrivit? Scrie-ne cerințele și îți răspundem cu o recomandare și un preț.

Solicită consultanță

Achiziții publice

Suntem înregistrați în SEAP și livrăm către instituții publice, cu documentație completă.

Cum cumperi prin SEAP →

Contact