Sari la conținut
Coșul meu

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Human CTLA4 ELISA Kit

Pe scurt

Human CTLA4 ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea CTLA4, cu reactivitate declarată pentru Human. Măsoară în domeniul 15.63 - 1000 pg/ml, are o sensibilitate de 7.13 pg/ml, folosește detecție Colorimetric și se poate folosi pe probe de tip Cell culture supernates, serum, EDTA plasma, heparin plasma. Se livrează în mărimea 96T, la prețul de 4.225,93 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Human CTLA4 ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human CTLA4 in cell culture supernates, serum, edta plasma, heparin plasma.

Citește mai multArată mai puțin

Specificații

Mărime
96T
Țintă
CTLA4
Applications
Sandwich ELISA
Reactivity
Human
Sensitivity
7.13 pg/ml
Detection type
Colorimetric
Product range
15.63 - 1000 pg/ml
Assay Time
4 hours
Principiul testului
Human CTLA4 ELISA Kit (A330009) employs the sandwich enzyme immunoassay technique for the quantitative measurement of human CTLA4 in cell culture supernates, serum, edta plasma, heparin plasma. An antibody specific for CTLA4 has been pre-coated onto a 96-well microtiter plate. The standards and test samples are added into the wells and the CTLA4 present in each sample is bound to the wells by the immobilized antibody. Following incubation, the wells are washed and then incubated with Biotinylated Anti-CTLA4 Antibody, which binds the captured CTLA4 present in each well. Following incubation, unbound biotinylated detection antibody is removed by washing, and an HRP-Streptavidin conjugate is added to the wells and the microtiter plate is incubated. Following incubation and washing, TMB substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is proportional to the amount of CTLA4 captured in each well. The concentration of CTLA4 can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.

Documentație

Produse similare

Ai nevoie de ajutor?

Nu găsești produsul potrivit? Scrie-ne cerințele și îți răspundem cu o recomandare și un preț.

Solicită consultanță

Achiziții publice

Suntem înregistrați în SEAP și livrăm către instituții publice, cu documentație completă.

Cum cumperi prin SEAP →

Contact