Human CNDP1/CN1 ELISA Kit

Pe scurt

Human CNDP1/CN1 ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea CNDP1/CN1, cu reactivitate declarată pentru Human. Măsoară în domeniul 3.12-200 ng/ml, are o sensibilitate de 1.45 ng/ml, folosește detecție Colourmetric și se poate folosi pe probe de tip Serum, plasma, cerebrospinal fluid or other biological fluids. Se livrează în mărimile 48T și 96T, la prețuri între 4.259,20 și 5.523,65 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Human CNDP1/CN1 ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human CNDP1/CN1 in serum, plasma, cerebrospinal fluid or other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărimi disponibile
48T · 96T
Țintă
CNDP1/CN1
Applications
Sandwich ELISA
Reactivity
Human
Sensitivity
1.45 ng/ml
Detection type
Colourmetric
Product range
3.12-200 ng/ml
Assay Time
4h 30m
Principiul testului
Human CNDP1/CN1 ELISA Kit (A4951) employs the sandwich enzyme immunoassay technique for the quantitative measurement of human CNDP1/CN1 in serum, plasma, cerebrospinal fluid or other biological fluids. An antibody specific for CNDP1/CN1 has been pre-coated onto a 96-well microtiter plate. The standards and test samples are added into the wells and the CNDP1/CN1 present in each sample is bound to the wells by the immobilized antibody. Following incubation, the wells are washed and then incubated with Biotinylated Anti-CNDP1/CN1 Antibody, which binds the captured CNDP1/CN1 present in each well. HRP-Avidin conjugate is then added to the wells and the microtiter plate is incubated. Following incubation and washing, TMB substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is proportional to the amount of CNDP1/CN1 captured in each well. The concentration of CNDP1/CN1 can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.