Human CCK ELISA Kit

Pe scurt

Human CCK ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea CCK, cu reactivitate declarată pentru Human. Măsoară în domeniul 3.906-250 pg/ml, are o sensibilitate de 2.344 pg/ml și folosește detecție Colorimetric Detection (OD450). Se livrează în mărimea 96T, la prețul de 3.746,77 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Human CCK ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human CCK in serum, plasma, cell culture supernatant, cell or tissue lysate, and other liquid samples.

Citește mai multArată mai puțin

Specificații

Mărime
96T
Țintă
CCK
Applications
Sandwich ELISA
Reactivity
Human
Sensitivity
2.344 pg/ml
Product range
3.906-250 pg/ml
Assay Time
4 hours
Principiul testului
Human CCK ELISA Kit (A335008) is a 4 hour sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human CCK in serum, plasma, cell culture supernatant, cell or tissue lysate, and other biological fluids. A 96-well microtiter plate has been pre-coated with an antibody specific for CCK. Standards and samples are added to the wells, where CCK binds to the immobilized capture antibody. Following incubation, unbound components are removed by washing and a biotinylated detection antibody specific for CCK is added to the wells. The detection antibody binds the captured CCK to form an antibody-antigen-antibody sandwich complex. After further incubation and washing, HRP-Streptavidin conjugate is added to the wells. TMB substrate solution is then added to visualize the HRP enzymatic reaction. This produces a blue-coloured product that changes to yellow following addition of acidic stop solution. The intensity of the yellow colour is directly proportional to the amount of CCK captured in each well. The concentration of CCK is calculated by reading the absorbance at 450 nm and comparing the values with the standard curve.