Human Carbonic Anhydrase 6/CA6 ELISA Kit

Pe scurt

Human Carbonic Anhydrase 6/CA6 ELISA Kit este un kit ELISA de tip Competitive (quantitative) pentru măsurarea Carbonic Anhydrase 6/CA6, cu reactivitate declarată pentru Human. Măsoară în domeniul 1 - 64 ng/ml, are o sensibilitate de 0.602 ng/ml, folosește detecție Colorimetric Detection (OD450) și se poate folosi pe probe de tip Serum, plasma, tissue homogenates, and other biological fluids. Se livrează în mărimea 96T, la prețul de 4.392,30 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Human Carbonic Anhydrase 6/CA6 ELISA Kit is a competitive Enzyme-Linked Immunosorbent Assay (cELISA) designed for the in vitro quantitative determination of human Carbonic Anhydrase 6/CA6 in serum, plasma, tissue homogenates, and other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărime
96T
Applications
Competitive ELISA
Reactivity
Human
Sensitivity
0.602 ng/ml
Product range
1 - 64 ng/ml
Assay Time
2 hours
Principiul testului
Human Carbonic Anhydrase 6/CA6 ELISA Kit (A77790) is a 2 hour competitive Enzyme-Linked Immunosorbent Assay (cELISA) designed for the in vitro quantitative determination of human Carbonic Anhydrase 6/CA6 in serum, plasma, tissue homogenates, and other biological fluids. A 96-well microtiter plate has been pre-coated with an antibody specific for Carbonic Anhydrase 6/CA6. During the assay, Carbonic Anhydrase 6/CA6 present in the standards or samples competes with a fixed amount of assay-specific detection reagent for binding to the immobilized antibody. Following incubation, unbound components are removed by washing and HRP-conjugated detection reagent is added to the wells. After further incubation and washing, TMB substrate solution is added to visualize the HRP enzymatic reaction. This produces a blue-coloured product that changes to yellow following addition of acidic stop solution. The intensity of the colour is measured at 450 nm using a microplate reader. The concentration of Carbonic Anhydrase 6/CA6 in the samples is inversely proportional to the OD450 value and is determined by comparison with the standard curve.