Sari la conținut
Coșul meu

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Human Cannabinoid Receptor II ELISA Kit

Pe scurt

Human Cannabinoid Receptor II ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea Cannabinoid Receptor II, cu reactivitate declarată pentru Human. Măsoară în domeniul 62.5-4000 pg/ml, are o sensibilitate de 24.5 pg/ml, folosește detecție Colourmetric și se poate folosi pe probe de tip Tissue homogenates, cell lysates or other biological fluids. Se livrează în mărimile 48T și 96T, la prețuri între 5.989,50 și 8.418,58 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Human Cannabinoid Receptor II ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human Cannabinoid Receptor II in tissue homogenates, cell lysates or other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărimi disponibile
48T · 96T
Applications
Sandwich ELISA
Reactivity
Human
Sensitivity
24.5 pg/ml
Detection type
Colourmetric
Product range
62.5-4000 pg/ml
Assay Time
4h 30m
Principiul testului
Human Cannabinoid Receptor II ELISA Kit (A270711) employs the sandwich enzyme immunoassay technique for the quantitative measurement of human Cannabinoid Receptor II in tissue homogenates, cell lysates or other biological fluids. An antibody specific for Cannabinoid Receptor II has been pre-coated onto a 96-well microtiter plate. The standards and test samples are added into the wells and the Cannabinoid Receptor II present in each sample is bound to the wells by the immobilized antibody. Following incubation, the wells are washed and then incubated with Biotinylated Anti-Cannabinoid Receptor II Antibody, which binds the captured Cannabinoid Receptor II present in each well. HRP-Avidin conjugate is then added to the wells and the microtiter plate is incubated. Following incubation and washing, TMB substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is proportional to the amount of Cannabinoid Receptor II captured in each well. The concentration of Cannabinoid Receptor II can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.

Documentație

Produse similare

Ai nevoie de ajutor?

Nu găsești produsul potrivit? Scrie-ne cerințele și îți răspundem cu o recomandare și un preț.

Solicită consultanță

Achiziții publice

Suntem înregistrați în SEAP și livrăm către instituții publice, cu documentație completă.

Cum cumperi prin SEAP →

Contact