Sari la conținut
Coșul meu

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Human C11B2/CYP11B2 ELISA Kit

Pe scurt

Human C11B2/CYP11B2 ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea C11B2/CYP11B2, cu reactivitate declarată pentru Human. Măsoară în domeniul 0.312-20 ng/ml, are o sensibilitate de 0.112 ng/ml, folosește detecție Colourmetric și se poate folosi pe probe de tip Serum, plasma, tissue homogenates or other biological fluids. Se livrează în mărimile 48T și 96T, la prețuri între 5.457,10 și 7.686,53 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Human C11B2/CYP11B2 ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human C11B2/CYP11B2 in serum, plasma, tissue homogenates or other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărimi disponibile
48T · 96T
Applications
Sandwich ELISA
Reactivity
Human
Sensitivity
0.112 ng/ml
Detection type
Colourmetric
Product range
0.312-20 ng/ml
Assay Time
4h 30m
Principiul testului
Human C11B2/CYP11B2 ELISA Kit (A270607) employs the sandwich enzyme immunoassay technique for the quantitative measurement of human C11B2/CYP11B2 in serum, plasma, tissue homogenates or other biological fluids. An antibody specific for C11B2/CYP11B2 has been pre-coated onto a 96-well microtiter plate. The standards and test samples are added into the wells and the C11B2/CYP11B2 present in each sample is bound to the wells by the immobilized antibody. Following incubation, the wells are washed and then incubated with Biotinylated Anti-C11B2/CYP11B2 Antibody, which binds the captured C11B2/CYP11B2 present in each well. HRP-Avidin conjugate is then added to the wells and the microtiter plate is incubated. Following incubation and washing, TMB substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is proportional to the amount of C11B2/CYP11B2 captured in each well. The concentration of C11B2/CYP11B2 can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.

Documentație

Produse similare

Ai nevoie de ajutor?

Nu găsești produsul potrivit? Scrie-ne cerințele și îți răspundem cu o recomandare și un preț.

Solicită consultanță

Achiziții publice

Suntem înregistrați în SEAP și livrăm către instituții publice, cu documentație completă.

Cum cumperi prin SEAP →

Contact