Sari la conținut
Coșul meu

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Human BAT3/BAG-6 ELISA Kit

Pe scurt

Human BAT3/BAG-6 ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea BAT3/BAG-6, cu reactivitate declarată pentru Human. Măsoară în domeniul 78.1-5000 pg/ml, are o sensibilitate de 36 pg/ml, folosește detecție Colourmetric și se poate folosi pe probe de tip Tissue homogenates, cell lysates or other biological fluids. Se livrează în mărimile 48T și 96T, la prețuri între 5.989,50 și 8.418,58 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Human BAT3/BAG-6 ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human BAT3/BAG-6 in tissue homogenates, cell lysates or other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărimi disponibile
48T · 96T
Țintă
BAT3/BAG-6
Applications
Sandwich ELISA
Reactivity
Human
Sensitivity
36 pg/ml
Detection type
Colourmetric
Product range
78.1-5000 pg/ml
Assay Time
4h 30m
Principiul testului
Human BAT3/BAG-6 ELISA Kit (A270707) employs the sandwich enzyme immunoassay technique for the quantitative measurement of human BAT3/BAG-6 in tissue homogenates, cell lysates or other biological fluids. An antibody specific for BAT3/BAG-6 has been pre-coated onto a 96-well microtiter plate. The standards and test samples are added into the wells and the BAT3/BAG-6 present in each sample is bound to the wells by the immobilized antibody. Following incubation, the wells are washed and then incubated with Biotinylated Anti-BAT3/BAG-6 Antibody, which binds the captured BAT3/BAG-6 present in each well. HRP-Avidin conjugate is then added to the wells and the microtiter plate is incubated. Following incubation and washing, TMB substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is proportional to the amount of BAT3/BAG-6 captured in each well. The concentration of BAT3/BAG-6 can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.

Documentație

Produse similare

Ai nevoie de ajutor?

Nu găsești produsul potrivit? Scrie-ne cerințele și îți răspundem cu o recomandare și un preț.

Solicită consultanță

Achiziții publice

Suntem înregistrați în SEAP și livrăm către instituții publice, cu documentație completă.

Cum cumperi prin SEAP →

Contact