Human ARTD10 ELISA Kit

Pe scurt

Human ARTD10 ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea ARTD10, cu reactivitate declarată pentru Human. Măsoară în domeniul 0.156-10 ng/ml, are o sensibilitate de 0.094 ng/ml și folosește detecție Colorimetric Detection (OD450). Se livrează în mărimea 96T, la prețul de 3.993,00 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Human ARTD10 ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human ARTD10 in serum, plasma, cell culture supernatant, cell or tissue lysate, and other liquid samples.

Citește mai multArată mai puțin

Specificații

Mărime
96T
Țintă
ARTD10
Applications
Sandwich ELISA
Reactivity
Human
Sensitivity
0.094 ng/ml
Product range
0.156-10 ng/ml
Assay Time
4 hours
Principiul testului
Human ARTD10 ELISA Kit (A326802) is a 4 hour sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human ARTD10 in serum, plasma, cell culture supernatant, cell or tissue lysate, and other biological fluids. A 96-well microtiter plate has been pre-coated with an antibody specific for ARTD10. Standards and samples are added to the wells, where ARTD10 binds to the immobilized capture antibody. Following incubation, unbound components are removed by washing and a biotinylated detection antibody specific for ARTD10 is added to the wells. The detection antibody binds the captured ARTD10 to form an antibody-antigen-antibody sandwich complex. After further incubation and washing, HRP-Streptavidin conjugate is added to the wells. TMB substrate solution is then added to visualize the HRP enzymatic reaction. This produces a blue-coloured product that changes to yellow following addition of acidic stop solution. The intensity of the yellow colour is directly proportional to the amount of ARTD10 captured in each well. The concentration of ARTD10 is calculated by reading the absorbance at 450 nm and comparing the values with the standard curve.