Human Apolipoprotein CI/Apo-CI ELISA Kit

Pe scurt

Human Apolipoprotein CI/Apo-CI ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea Apolipoprotein CI/Apo-CI, cu reactivitate declarată pentru Human. Măsoară în domeniul 4.68-300 ng/ml, are o sensibilitate de 2.2 ng/ml, folosește detecție Colourmetric și se poate folosi pe probe de tip Serum, plasma or other biological fluids. Se livrează în mărimile 48T și 96T, la prețuri între 3.959,73 și 5.190,90 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Human Apolipoprotein CI/Apo-CI ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human Apolipoprotein CI/Apo-CI in serum, plasma or other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărimi disponibile
48T · 96T
Applications
Sandwich ELISA
Reactivity
Human
Sensitivity
2.2 ng/ml
Detection type
Colourmetric
Product range
4.68-300 ng/ml
Assay Time
4h 30m
Principiul testului
Human Apolipoprotein CI/Apo-CI ELISA Kit (A3118) employs the sandwich enzyme immunoassay technique for the quantitative measurement of human Apolipoprotein CI/Apo-CI in serum, plasma or other biological fluids. An antibody specific for Apolipoprotein CI/Apo-CI has been pre-coated onto a 96-well microtiter plate. The standards and test samples are added into the wells and the Apolipoprotein CI/Apo-CI present in each sample is bound to the wells by the immobilized antibody. Following incubation, the wells are washed and then incubated with Biotinylated Anti-Apolipoprotein CI/Apo-CI Antibody, which binds the captured Apolipoprotein CI/Apo-CI present in each well. HRP-Avidin conjugate is then added to the wells and the microtiter plate is incubated. Following incubation and washing, TMB substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is proportional to the amount of Apolipoprotein CI/Apo-CI captured in each well. The concentration of Apolipoprotein CI/Apo-CI can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.