Human AMH ELISA Kit

Pe scurt

Human AMH ELISA Kit este un kit ELISA de tip Competitive (quantitative) pentru măsurarea AMH, cu reactivitate declarată pentru Human. Măsoară în domeniul 46.8-3000 pg/ml, are o sensibilitate de 23.2 pg/ml și folosește detecție Colourmetric. Se livrează în mărimile 48T și 96T, la prețuri între 3.959,73 și 5.190,90 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Human AMH ELISA Kit is a competitive Enzyme-Linked Immunosorbent Assay (cELISA) designed for the in vitro quantitative determination of human AMH in serum, plasma, tissue homogenates, cell lysates, cell culture supernates or other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărimi disponibile
48T · 96T
Țintă
AMH
Applications
Competitive ELISA
Reactivity
Human
Sensitivity
23.2 pg/ml
Detection type
Colourmetric
Product range
46.8-3000 pg/ml
Assay Time
2h 30m
Principiul testului
Human AMH ELISA Kit (A3114) employs the competitive enzyme immunoassay technique for the quantitative measurement of human AMH in serum, plasma, tissue homogenates, cell lysates, cell culture supernates or other biological fluids. The 96-well microtiter plate has been pre-coated with AMH antigen. During the incubation, AMH present in the samples or standards competes with the fixed amount of immobilized AMH for binding sites on the Biotinylated Anti-AMH Antibody. The more AMH present in a sample or standard, the less Biotinylated Anti-AMH Antibody that binds to the plate. Following incubation, unbound Biotinylated Anti-AMH Antibody is removed by washing, and an HRP-Avidin conjugate is added to the wells and the microtiter plate is incubated. Following incubation and washing, TMB substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is inversely proportional to the amount of AMH present in each sample or standard. The concentration of AMH can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.