Human Adropin ELISA Kit

Pe scurt

Human Adropin ELISA Kit este un kit ELISA de tip Competitive (quantitative) pentru măsurarea Adropin, cu reactivitate declarată pentru Human. Măsoară în domeniul 0.156-10 ng/ml, are o sensibilitate de 0.065 ng/ml, folosește detecție Colourmetric și se poate folosi pe probe de tip Serum, plasma, tissue homogenates or other biological fluids. Se livrează în mărimile 48T și 96T, la prețuri între 4.525,40 și 5.989,50 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Human Adropin ELISA Kit is a competitive Enzyme-Linked Immunosorbent Assay (cELISA) designed for the in vitro quantitative determination of human Adropin in serum, plasma, tissue homogenates or other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărimi disponibile
48T · 96T
Țintă
Adropin
Applications
Competitive ELISA
Reactivity
Human
Sensitivity
0.065 ng/ml
Detection type
Colourmetric
Product range
0.156-10 ng/ml
Assay Time
2h 30m
Principiul testului
Human Adropin ELISA Kit (A6034) employs the competitive enzyme immunoassay technique for the quantitative measurement of human Adropin in serum, plasma, tissue homogenates or other biological fluids. The 96-well microtiter plate has been pre-coated with Adropin antigen. During the incubation, Adropin present in the samples or standards competes with the fixed amount of immobilized Adropin for binding sites on the Biotinylated Anti-Adropin Antibody. The more Adropin present in a sample or standard, the less Biotinylated Anti-Adropin Antibody that binds to the plate. Following incubation, unbound Biotinylated Anti-Adropin Antibody is removed by washing, and an HRP-Avidin conjugate is added to the wells and the microtiter plate is incubated. Following incubation and washing, TMB substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is inversely proportional to the amount of Adropin present in each sample or standard. The concentration of Adropin can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.