Sari la conținut
Coșul meu

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Guinea Pig Cholecystokinin 8 ELISA Kit

Pe scurt

Guinea Pig Cholecystokinin 8 ELISA Kit este un kit ELISA de tip Competitive (quantitative) pentru măsurarea Cholecystokinin 8, cu reactivitate declarată pentru Guinea Pig. Măsoară în domeniul 15.6-1000 pg/ml, are o sensibilitate de 5.28 pg/ml, folosește detecție Colourmetric și se poate folosi pe probe de tip Serum, plasma, tissue homogenates, cell culture supernates or other biological fluids. Se livrează în mărimile 48T și 96T, la prețuri între 4.492,13 și 5.922,95 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Guinea Pig Cholecystokinin 8 ELISA Kit is a competitive Enzyme-Linked Immunosorbent Assay (cELISA) designed for the in vitro quantitative determination of guinea pig Cholecystokinin 8 in serum, plasma, tissue homogenates, cell culture supernates or other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărimi disponibile
48T · 96T
Applications
Competitive ELISA
Reactivity
Guinea Pig
Sensitivity
5.28 pg/ml
Detection type
Colourmetric
Product range
15.6-1000 pg/ml
Assay Time
2h 30m
Principiul testului
Guinea Pig Cholecystokinin 8 ELISA Kit (A7630) employs the competitive enzyme immunoassay technique for the quantitative measurement of guinea pig Cholecystokinin 8 in serum, plasma, tissue homogenates, cell culture supernates or other biological fluids. The 96-well microtiter plate has been pre-coated with Cholecystokinin 8 antigen. During the incubation, Cholecystokinin 8 present in the samples or standards competes with the fixed amount of immobilized Cholecystokinin 8 for binding sites on the Biotinylated Anti-Cholecystokinin 8 Antibody. The more Cholecystokinin 8 present in a sample or standard, the less Biotinylated Anti-Cholecystokinin 8 Antibody that binds to the plate. Following incubation, unbound Biotinylated Anti-Cholecystokinin 8 Antibody is removed by washing, and an HRP-Avidin conjugate is added to the wells and the microtiter plate is incubated. Following incubation and washing, TMB substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is inversely proportional to the amount of Cholecystokinin 8 present in each sample or standard. The concentration of Cholecystokinin 8 can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.

Documentație

Produse similare

Ai nevoie de ajutor?

Nu găsești produsul potrivit? Scrie-ne cerințele și îți răspundem cu o recomandare și un preț.

Solicită consultanță

Achiziții publice

Suntem înregistrați în SEAP și livrăm către instituții publice, cu documentație completă.

Cum cumperi prin SEAP →

Contact