Imagine indisponibilăFlumequine ELISA Kit
Pe scurt
Flumequine ELISA Kit este un kit ELISA de tip Competitive (quantitative) pentru măsurarea Flumequine. Măsoară în domeniul Detection Limit is 0.1 ng/g, folosește detecție Colorimetric și se poate folosi pe probe de tip Egg, honey, meat, milk, urine and various sample types. Se livrează în mărimea 96T, la prețul de 2.562,18 lei cu TVA.
Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.
Descriere
Flumequine ELISA Kit is a competitive Enzyme-Linked Immunosorbent Assay (cELISA) designed for the in vitro quantitative determination of Flumequine in egg, honey, meat, milk, urine and various sample types.
Citește mai multArată mai puțin
Specificații
- Brand
- Antibodies
- Mărime
- 96T
- Țintă
- Flumequine
- Applications
- Competitive ELISA
- Assay type
- Competitive (quantitative)
- Detection type
- Colorimetric
- Product range
- Detection Limit is 0.1 ng/g.
- Assay Time
- 10-60 minutes
- Recovery
- 75-105%
- Principiul testului
- Flumequine ELISA Test Kit (A327207) employs the competitive enzyme immunoassay technique for the quantitative measurement of Flumequine in egg, honey, meat, milk, urine and various sample types. The 96-well microtiter plate has been pre-coated with Flumequine. During the incubation, Flumequine present in the samples or standards competes with the fixed amount of immobilized Flumequine for binding sites of the Anti-Flumequine Antibody, a HRP-Conjugated Secondary Antibody is added to the wells at the same time. The more Flumequine present in a sample or standard, the less Anti-Flumequine Antibody that binds to the plate. Following incubation, unbound HRP-Conjugated Secondary Antibody is removed by washing. Following incubation and washing, TMB substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is inversely proportional to the amount of Flumequine present in each sample or standard. The concentration of Flumequine can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.