Sari la conținut
Coșul meu

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

CORT ELISA Kit

Pe scurt

CORT ELISA Kit este un kit ELISA de tip Competitive (quantitative) pentru măsurarea CORT, cu reactivitate declarată pentru Universal. Măsoară în domeniul 7.81 - 500 ng/ml, are o sensibilitate de 2.62 ng/ml, folosește detecție Colourmetric și se poate folosi pe probe de tip Serum, plasma, urine or other biological fluids. Se livrează în mărimile 48T și 96T, la prețuri între 3.893,18 și 5.124,35 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

CORT ELISA Kit is a competitive Enzyme-Linked Immunosorbent Assay (cELISA) designed for the in vitro quantitative determination of CORT in serum, plasma, urine or other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărimi disponibile
48T · 96T
Țintă
CORT
Applications
Competitive ELISA
Reactivity
Universal
Sensitivity
2.62 ng/ml
Detection type
Colourmetric
Product range
7.81 - 500 ng/ml
Assay Time
2h 30m
Principiul testului
CORT ELISA Kit (A5981) employs the competitive enzyme immunoassay technique for the quantitative measurement of CORT in serum, plasma, urine or other biological fluids. The 96-well microtiter plate has been pre-coated with CORT antigen. During the incubation, CORT present in the samples or standards competes with the fixed amount of immobilized CORT for binding sites on the Biotinylated Anti-CORT Antibody. The more CORT present in a sample or standard, the less Biotinylated Anti-CORT Antibody that binds to the plate. Following incubation, unbound Biotinylated Anti-CORT Antibody is removed by washing, and an HRP-Avidin conjugate is added to the wells and the microtiter plate is incubated. Following incubation and washing, TMB substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is inversely proportional to the amount of CORT present in each sample or standard. The concentration of CORT can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.

Documentație

Produse similare

Ai nevoie de ajutor?

Nu găsești produsul potrivit? Scrie-ne cerințele și îți răspundem cu o recomandare și un preț.

Solicită consultanță

Achiziții publice

Suntem înregistrați în SEAP și livrăm către instituții publice, cu documentație completă.

Cum cumperi prin SEAP →

Contact