Pe scurt

Human MDC ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea MDC, cu reactivitate declarată pentru Human. Măsoară în domeniul 31.2-2000 pg/ml, are o sensibilitate de < 1 pg/ml, folosește detecție Colorimetric și se poate folosi pe probe de tip Serum, plasma, body fluids, tissue lysates, and cell culture supernatants. Se livrează în mărimea 96T, la prețul de 4.225,93 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Human MDC ELISA Kit is a sandwhich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human MDC in serum, plasma, body fluids, tissue lysates, and cell culture supernatants.

Citește mai multArată mai puțin

Specificații

Mărime
96T
Țintă
MDC
Applications
Sandwhich ELISA
Reactivity
Human
Sensitivity
< 1 pg/ml
Detection type
Colorimetric
Platform
Microplate
Product range
31.2-2000 pg/ml
Principiul testului
This MDC enzyme linked immunosorbent assay (ELISA) applies a technique called a quantitative sandwich immunoassay. The microtiter plate has been pre-coated with an Anti-MDC Antibody. Standards or samples are then added to the microtire plate wells and MDC, if present, will bind to the antibody pre-coated on the wells. In order to quantify the amount of MDC present in the sample, Anti-MDC Antibody (Biotin) is added to each well to "sandwich" the MDC immobilised on the plate. The microtiter plate then undergoes incubation, followed by thorough washing of the wells to remove all unbound components. Next, Avidin-Biotin-Peroxidase Complex is added to each well for a short incubation period, followed by thorough washing of the wells to remove all unbound conjugates. Next, a TMB (3,3',5,5' tetramethyl-benzidine) substrate solution is added to each well. The enzyme (HRP) and substrate are allowed to react over a short incubation period. Only those wells that contain MDC will exhibit a change in colour. The enzyme-substrate reaction is terminated by the addition of a stop solution and the colour change is measured spectrophotometrically at a wavelength of 450nm ± 2nm.