Nu există produse adăugate.

Inregistreaza-te sau intra in cont pentru a vedea si modifica comenzile si informatiile personale.
Mouse Granulocyte Macrophage Colony Stimulating Factor ELISA Kit (A33048-1923)
Cod: A33048-1923
Numar teste: 192T x 3
11.324,04 Lei
Timp de livrare: 2-3 saptamani
Preturile includ TVA 19%
Cere oferta
This mouse GM-CSF enzyme linked immunosorbent assay (ELISA) applies a technique called a quantitative sandwich immunoassay. The microtiter plate provided in this kit has been pre-coated with a monoclonal antibody specific for mouse GM-CSF. Standards or samples are then added to the appropriate microtiter plate wells and incubated. Mouse GM-CSF, if present, will bind and become immobilized by the antibody pre-coated on the wells. The microtiter plate wells are thoroughly washed to remove unbound mouse GM-CSF and other components of the sample. In order to quantitatively determine the amount of mouse GM-CSF present in the sample, a standardized preparation of horseradish peroxidase HRP-conjugated monoclonal antibody specific for mouse GM-CSF is added to each well to “sandwich” the mouse GM-CSF immobilized during the first incubation. The microtiter plate then undergoes a second incubation. The wells are thoroughly washed to remove all unbound HRP-conjugated antibodies and a TMB(3,3’5,5’ tetramethyl-benzidine) substrate solution is added to each well. The enzyme (HRP) and substrate are allowed to react over a short incubation period. Only those wells that contain mouse GM-CSF and enzyme-conjugated antibody will exhibit a change in colour. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution and the colour change is measured spectrophotometrically at a wavelength of 450 ± 2 nm.

In order to measure the concentration of mouse GM-CSF in the samples, this kit includes two diluents (Calibrator Diluent I for serum/plasma testing and Calibrator Diluent II for cell culture supernatant testing). According to the testing system, the provided standard is diluted (2-fold dilution series) with the appropriate Calibrator Diluent and assayed at the same time as the samples. This allows the operator to produce a standard curve of Optical Density (O.D.) versus mouse GM-CSF concentration (pg/mL). The concentration of mouse GM-CSF in the samples is then determined by comparing the O.D. of the samples to the standard curve.
  • Serum, cell culture supernatant and other biological fluids.
  • ANTIBODIES
  • Sandwich (quantitative)
  • 50-3200 pg/ml
  • < 17 pg/ml
Trebuie să fiţi autentificat pentru a putea adaugă comentarii.