Human Transforming Growth Factor beta 1 ELISA Kit (A33014-192)
Cod: A33014-192
Numar teste:
192T
5.631,08 Lei
Timp de livrare: 2-3 saptamani
Preturile includ TVA 19%
This TGF-β1 enzyme linked immunosorbent assay (ELISA) applies a technique called a quantitative sandwich immunoassay. The microtiter plate provided in this kit has been pre-coated with a monoclonal antibody specific to TGF-β1. Standards or samples are then added to the appropriate microtiter plate wells and incubated. After washing, biotin conjugated polyclonal antibody specific to TGF-β1 is added and incubated. TGF-β1 if present, will bind and become immobilized by the antibody pre-coated on the wells and then be “sandwiched” by biotin conjugate. The microtiter plate wells are thoroughly washed to remove unbound TGF-β1 and other components of the sample. In order to quantitatively determine the amount of TGF-β1 present in the sample, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Avidin is a tetramer containing four identical subunits that each has a high affinity-binding site for biotin. The wells are thoroughly washed to remove all unbound HRP-conjugated Avidin and a TMB (3,3'5,5' tetramethyl-benzidine) substrate solution is added to each well. The enzyme (HRP) and substrate are allowed to react over a short incubation period. Only those wells that contain TGF-β1, biotin-conjugated antibody, and enzyme-conjugated Avidin will exhibit a change in colour. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution and the colour change is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm.
In order to measure the concentration of TGF-β1 in the samples, this kit includes two calibration diluents (Calibrator Diluent I for serum/plasma testing and Calibrator Diluent II for cell culture supernatant testing.) According to the testing system, the provided standard is diluted (2-fold) with the appropriate Calibrator Diluent and assayed at the same time as the samples. This allows the operator to produce a standard curve of Optical Density (O.D) versus TGF-β1 concentration (pg/mL). The concentration of TGF- β1 in the samples is then determined by comparing the O.D. of the samples to the standard curve.
In order to measure the concentration of TGF-β1 in the samples, this kit includes two calibration diluents (Calibrator Diluent I for serum/plasma testing and Calibrator Diluent II for cell culture supernatant testing.) According to the testing system, the provided standard is diluted (2-fold) with the appropriate Calibrator Diluent and assayed at the same time as the samples. This allows the operator to produce a standard curve of Optical Density (O.D) versus TGF-β1 concentration (pg/mL). The concentration of TGF- β1 in the samples is then determined by comparing the O.D. of the samples to the standard curve.
- Serum, plasma, cell culture supernatant, and other biological fluids.
- ANTIBODIES
- Sandwich (quantitative)
- 9- 2500 pg/ml
- < 9 pg/ml